• Chziri 115kw AC Motor Starter Zjr2-B
  • Chziri 115kw AC Motor Starter Zjr2-B
  • Chziri 115kw AC Motor Starter Zjr2-B
  • Chziri 115kw AC Motor Starter Zjr2-B
  • Chziri 115kw AC Motor Starter Zjr2-B
  • Chziri 115kw AC Motor Starter Zjr2-B

Chziri 115kw AC Motor Starter Zjr2-B

Task: Protection
Structure: Combination
Mathematical Model: Non-Linear
Signal: Continuous
Certification: CCC, ISO: 9001, CE
Condition: New
Samples:
US$ 200/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Installation Instructions
  • FAQ
  • Our Advantages
  • Hot recommend
Overview

Basic Info.

Model NO.
ZJR2-B
Customized
Non-Customized
Material
Plastic Case
Power Range
5.5kw~600kw
Input Voltage
380V,440V
Input Frequency
50/60Hz
Transport Package
Standard Export Package
Specification
CE
Trademark
CHZIRI
Origin
China
HS Code
8537101990
Production Capacity
50000PCS/Year

Product Description

Chziri 115kw AC Motor Starter Zjr2-B
Product Description

CHZIRI AC Motor Starter have the following Main Features:


AC Motor Starter can work with three-phase, AC squirrel cage induction asynchronous motor, The voltage is 320V~460V, 50HZ/60HZ and the current is 1200A and below. The soft starter is a device type. It's necessary to add breakers (short-circuit protection ) and AC contactor (Bypass) inside the cabinet. Together with switches are made up of electric motor control circuit.

1 AC Motor Starter can work without three-phase AC motor in the process of starting too big acceleration torque, and power supply system plays a protection from excessive current harvest dynamic impact role, has the following characteristics:
1.AC Motor Starter have 16 SCM control, intelligent all-digital display;
2.AC Motor Starter Can be put into practice a soft starter control multiple motors;
3. AC Motor Starter have the Starting modes: Current limiting starter, Voltage ramp start, Kick start +current-limiting start, kick start +voltage ramp start. Current ramp start. Voltage current-limiting double closed loop start.
4. AC Motor Starter have the function of Free stop and soft stop, The stop time from 0 to 60 seconds can be arbitrary choosed.
5. AC Motor Starter have the function of Over current, Overload, Open phase, instantaneous stop and other fault protection. With the flow, over loading, lack phase, instantaneous stop, and other malfunction protection;
6. Easy installation, simple operation, strong function and reasonable prices for 115kW AC Motor Starter


Scope of application for 115kW AC Motor Starter

115kW AC Motor Starter applies to centrifuges, blower, compressor, transport planes, mixer, rolling ball mill broken machines and mechanical equipment motor starter.
Item Item Description
Input Power Supply Input Voltage Three-phase 380V-15% ~415+10%
Frequency 50/60Hz
Adaptive Motor Squirrel-cage three-phase asynchronous motor
Starting Times It is recommended not to exceed 20 times per hour.
Control Mode 1) Operation panel control; 2) Operation panel + external control; 3) External control; 4) External control + COM control; 5) Operation panel + external + COM control; 6) Operation panel + COM control; 7) COM control; 8) No start or stop operation.
Start Mode 1) Current-limiting start; 2) Voltage ramp start; 3) Kick start + current-limiting start; 4) Kick start + voltage ramp start; 5) Current ramp start; 6) Voltage current-limiting double closed-loop start.
Stop Mode 1) Soft stop; 2) Free stop.
Protective Function Open loop protection for external instantaneous stop terminals; 2) Over-heat protection for soft starter; 3) Protection for too long starting time; 4) Input open phase protection; 5) Output open phase protection; 6) Unbalanced three-phase protection; 7) starting over current protection; 8) Running overload protection; 9) Under voltage protection for power voltage; 10) Over voltage protection for power voltage;11) Protectionfor fault parameter setting; 12) Load short circuit protection; 13) Auto restart or incorrect wiring protection; 14) Incorrect wiring protection of external control stop terminals.
Ambient Place to be used Indoor location with good ventilation free from corrosive gas and conductivedust.
Altitude Below 3000M. It have to rise the rate power when the altitude is more than 3000M.
Ambient
Temperature
 
-30~+55 C
Ambient Humidity ≤90%RH without dew condensation.
Vibration <0.5G
Structure Protection Class IP20
Cooling Pattern Natural wind cooling.

Soft  Starter Description
ZJR2 series soft starter can work with three-phase ,AC squirrel cage induction asynchronous motor ,The voltage is 320V~460V, 50HZ/60HZ and the current is 1200A and below .
ZJR2 series soft starter are in the process of motor starting and running a perfect protection function, adopted the closed loop control, greatly improving the stationarity of soft starting torque of the motor

The soft starter is a device type .It's necessary to add breakers (short-circuit protection ) and AC contactor (Bypass) inside the cabinet . together with switches are made up of electric motor control circuit .

  Main Features for  ZJR2 series soft starter

1. 16 SCM control, intelligent all-digital display;
2. can be put into practice a soft starter control multiple motors;
3. Starting modes: Current limiting starter, Voltage ramp start , Kick start +current-limiting  start,  kick start +voltage ramp start  . Current ramp start . Voltage current-limiting double closed -loop start .
4. free stop  and soft stop , The stop time from  0 to 60 seconds can be arbitrary choosed .
5. Over current , Overload , Open phase, instantaneous stop and other fault protection .
with the flow, over loading, lack phase, instantaneous stop, and other malfunction protection;
6. Easy installation, simple operation, strong function and reasonable prices;


  
 Soft Starter Dimension (Unit:mm)
Chziri 115kw AC Motor Starter Zjr2-B
 

Guide Model for ZJR2 Soft Starter
 
Soft starter Model Rated Power(KW) Voltage(V) Rated Current (A) Outline Size Install Size
H1 W1 D H2 W2 d
ZJR2-B3055 5.5kW 380V 11 270 145 159 245 130 M6
ZJR2-B3075 7.5kW 380V 15 270 145 159 245 130 M6
ZJR2-B3110 11kW 380V 22 270 145 159 245 130 M6
ZJR2-B3150 15kW 380V 30 270 145 159 245 130 M6
ZJR2-B3185 18.5kW 380V 37 270 145 159 245 130 M6
ZJR2-B3220 22kW 380V 44 270 145 159 245 130 M6
ZJR2-B3300 30kW 380V 60 270 145 159 245 130 M6
ZJR2-B3370 37kW 380V 75 270 145 159 245 130 M6
ZJR2-B3450 45kW 380V 90 270 145 159 245 130 M6
ZJR2-B3550 55kW 380V 110 270 145 159 245 130 M6
Chziri 115kw AC Motor Starter Zjr2-BChziri 115kw AC Motor Starter Zjr2-B
Installation Instructions

Soft Starter wiring diagram

Chziri 115kw AC Motor Starter Zjr2-B


Chziri 115kw AC Motor Starter Zjr2-B
Scope of application:
ZJR2 series soft starter motor applies to centrifuges, blower, compressor, transport planes, mixer, rolling ball mill broken machines and mechanical equipment motor starter.
Chziri 115kw AC Motor Starter Zjr2-B
FAQ

FAQ                        

1.   Can I get some samples?
Yes, Sample order is available for quality check and market test .But you have to pay for it .
2.   What's delivery time?
It usually takes about 3-5 working days for small order and 10-15 days for big order .
3.   What's your payment terms?
We usually accept all kinds of payment terms .Such as T/T,L/C, Western Union.Cash.
4.   What's your warranty terms?
We offer 12 months warranty time .
5.   Do you have the products in stock?
Depends on your request ,We have standard models in stock. Some special products and big order will be newly produced according to your order .
6.   Can I mix different power in one container .
Yes ,Different models can be mixed up in one container ,even one order .
7.   How does your factory do the quality control?
Quality is priority ,we always attach the importance to quality control from the beginning to the end of the production .every product will be fully assembled and carefully tested before packing and shipping .
8.   Can you sell spare parts ?
If you are using CHZIRI products .we can sell spare parts to you . But we couldn't sell the half-finished products.
9.I would like to know if you have a partner for export?
Yes .CHZIRI Electrical have the right to export and can sell electrical product all over the world..
10. Can you make the inverter and soft starter control boards (switchgear)?
Yes. We have a lot of experience to design frequency inverter and soft starter cabinet according to your request . But you can send us the wiring diagram .
11.Can the inverter connect with computer?
Yes .All inverters have built-in RS485 port .and support Modbus communication protocol.
12.How can I trust you ?
The core of CHZIRI electrical culture is honesty and loyalty .our company has been audited and approved ISO9001,CE.CCC. Assessment report will could be sent to you by e-mail .also .we are the made-in-china's gold supplier since 2008.Now we have clients all around the world .
 
Our Advantages

 CHZIRI Clients


Chziri 115kw AC Motor Starter Zjr2-BChziri 115kw AC Motor Starter Zjr2-BChziri 115kw AC Motor Starter Zjr2-B
Hot recommend

Chziri 115kw AC Motor Starter Zjr2-B

Chziri 115kw AC Motor Starter Zjr2-B
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now