Customization: | Available |
---|---|
Task: | Protection |
Structure: | Combination |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
AC Soft Starter kW can work with three-phase AC motor in the process of starting too big acceleration torque, and power supply system plays a protection from excessive current harvest dynamic impact role,
Through controlling the conductive angle of three phase anti-parallel thyristor that is connected in series between power supply and the controlled motor. AC Soft Starter 75kW make the terminal voltage of motor rise to the rated voltage from the preset value. Reaching the aim of smooth starting by reducing current during the starting process. It belongs to the category of reduced-voltage starting. Hence. Starting torque would be reduced somewhat. It is suitable for locations where are not strict with starting torque. In order to obtain the optimum efficiency of AC Soft Starter
Main Features for ZJR2 series soft starter
1. 16 SCM control, intelligent all-digital display;
2. can be put into practice a soft starter control multiple motors;
3. Starting modes: Current limiting starter, Voltage ramp start , Kick start +current-limiting start, kick start +voltage ramp start . Current ramp start . Voltage current-limiting double closed -loop start .
4. free stop and soft stop , The stop time from 0 to 60 seconds can be arbitrary choosed .
5. Over current , Overload , Open phase, instantaneous stop and other fault protection .
with the flow, over loading, lack phase, instantaneous stop, and other malfunction protection;
6. Easy installation, simple operation, strong function and reasonable prices;
Item | Item Description | ||
Input Power Supply | Input Voltage | Three Phase 380V-15% ~ 415+10% | |
Frequency | 50/60Hz | ||
Adaptive Motor | Squirrel-cage three-phase asynchronous motor | ||
Starting Times | It is recommended not to exceed 20 times per hour. | ||
Control Mode | 1) Operation panel control; 2) Operation panel + external control; 3) External control; 4) External control + COM control; 5) Operation panel + external + COM control; 6) Operation panel + COM control; 7) COM control; 8) No start or stop operation. | ||
Start Mode | 1) Current-limiting start; 2) Voltage ramp start; 3) Kick start + current-limiting start; 4) Kick start + voltage ramp start; 5) Current ramp start; 6) Voltage current-limiting double closed-loop start. | ||
Stop Mode | 1) Soft stop; 2) Free stop. | ||
Protective Function | 1) Open loop protection for external instantaneous stop terminals; 2) Over-heat protection for soft starter; 3) Protection for too long starting time; 4) Input open phase protection; 5) Output open phase protection; 6) Unbalanced three-phase protection; 7) starting over current protection; 8) Running overload protection; 9) Under voltage protection for power voltage; 10) Over voltage protection for power voltage; 11) Protection for fault parameter setting; 12) Load short circuit protection; 13) Auto restart or incorrect wiring protection; 14) Incorrect wiring protection of external control stop terminals. | ||
Ambient | Place to be used | Indoor location with good ventilation free from corrosive gas and conductive dust. | |
Altitude | Below 3000M. It have to rise the rate power when the altitude is more than 3000M. | ||
Ambient Temperature |
-30~+55ºC |
||
Ambient Humidity | ≤90%RH without dew condensation. | ||
Vibration | <0.5G | ||
Structure | Protection Class | IP20 | |
Cooling Pattern | Natural wind cooling. |
Soft Starter Dimension (Unit:mm)
Soft starter Model | Voltage(V) | Rated Power(KW) | Rated Current (A) | Outline Size(mm) | Install Size(mm) | ||||
H1 | W1 | D | H2 | W2 | d | ||||
ZJR2-B3055 | 380V | 5.5 | 11 | 270 | 145 | 159 | 245 | 130 | M6 |
ZJR2-B3075/ | 380V | 7.5 | 15 | 270 | 145 | 159 | 245 | 130 | M6 |
ZJR2-B3110 | 380V | 11 | 22 | 270 | 145 | 159 | 245 | 130 | M6 |
ZJR2-B3150 | 380V | 15 | 30 | 270 | 145 | 159 | 245 | 130 | M6 |
ZJR2-B3185 | 380V | 18.5 | 37 | 270 | 145 | 159 | 245 | 130 | M6 |
ZJR2-B3220 | 380V | 22 | 44 | 270 | 145 | 159 | 245 | 130 | M6 |
ZJR2-B3300 | 380V | 30 | 60 | 270 | 145 | 159 | 245 | 130 | M6 |
ZJR2-B3370 | 380V | 37 | 75 | 270 | 145 | 159 | 245 | 130 | M6 |
ZJR2-B3450 | 380V | 45 | 90 | 270 | 145 | 159 | 245 | 130 | M6 |
ZJR2-B3550 | 380V | 55 | 110 | 270 | 145 | 159 | 245 | 130 | M6 |
1. low voltage frequency inverter and soft starter manufacturer and exporter.
2. More than 15 years experience and professional devoting the automation control system. we want to be the best to serve our clients.
3. CHZIRI frequency inverter and soft starters are certificated with CE. CHZIRI Electrical passed ISO9001:2008 quality control system.
4.CHZIRI Electrical are near to NINGBO ,SHANGHAI port .The shipping cost will be cheaper.
Q1.Can I get some samples?
Yes, Sample order is available for quality check and market test.