Customization: | Available |
---|---|
Output Type: | Triple |
Principle of Work: | AC Inverter |
Still deciding? Get samples of US$ 886/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item | Item Description | |
Control Function | Automatic energy-saving operation | Auto optimize V/F curve according to the load changes to realize the energy saving operation. |
Auto voltage regulation(AVR) | When the network voltage changes, it can regulate PWM output automatically to maintain constant voltage. | |
Built-in PID | This can form a convenient closed-loop control system (CLCS)and is applicable to pressure control, flow control and other process control . | |
Operation Function | Operating command | Operation panel control ,external terminal control and COM control |
Frequency setting | Keypad potentiometer setting , operation panel UP ,DOWN setting,. external terminal UP/DOWN setting, analog voltage signal or external potentiometer setting , analog current signal setting .terminal combination setting ,485 COM setting and so on. | |
Input Signal | Forward/Reverse signal\multi-speed signal \fault signal \ reset signal etc. |
|
Output signal | Programmable relay\open collector output \Fault signal output. | |
Multi-function analog and digital output terminal | This can realize the output of frequency current and other physical quantity by output 0-10V or 0-20mA DC signal and 0-10KHz digital signal output. | |
Braking function | Dynamic braking | With an external braking resistor, the maximum braking torque may reach 100%. |
DC Braking | This can be selected when the motor starts or stops with the action frequency of 0-20Hz,action current level of 0-100% and actuation time of 0-30sec., which can be set in sequence. | |
Other Function | Skip frequency\Jog function\Counter \Rotation speed tracking\Momentary power loss restart \Frequency upper/lower limiting\Acceleration/ Deceleration mode can be adjusted \Frequency meter and Voltmeter output \Multi-speed/ program running \Two wire mode/ three wire mode control \Wobble frequency control\Multi-function input terminal selection \Fault auto reset\RS485 serial communication . | |
Protection Function | Input phase loss protection\Over current protection \Overload protection\Over voltage protection \Under voltage protection\Over heat protection ect. |
Inverter Model | Power (KW) G/P |
Current (A) |
Dimension (mm) | |||||
H | H1 | W | W1 | D | d | |||
ZVF300-G045/P055T4M | 45/55 | 90/110 | 620 | 603 | 265 | 182 | 300 | 8 |
Inverter Model | Voltage | Power | Current | Dimension (mm) | Packing Size(mm) | G.W.(kg) | |||||
(V) | (KW) | ( A) | H | H1 | W | W1 | D | d | |||
ZVF330-M0R4S2MD | 220V | 0.4 | 2.4 | 141.5 | 130.5 | 85 | 74 | 125 | 5 | 570*380*460mm/16PCS | 25kg |
ZVF330-M0R7S2MD | 0.75 | 4 | 141.5 | 130.5 | 85 | 74 | 125 | 5 | |||
ZVF330-M1R5S2SD | 1.5 | 7.5 | 151 | 140 | 100 | 89.5 | 128.5 | 5 | |||
ZVF330-M2R2S2SD | 2.2 | 10 | 151 | 140 | 100 | 89.5 | 128.5 | 5 |