Model | Rated Power(KW) | Rated Current (A) | Outline Size | Install Size | Net Weight (KG) |
||||
H1 | W1 | D | H2 | W2 | d | ||||
ZJR2-3750 | 75 | 150 | 530 | 260 | 202 | 380 | 196 | M8 | <25 |
ZJR2-3900 | 90 | 180 | 530 | 260 | 202 | 380 | 196 | M8 | <25 |
ZJR2-31150 | 115 | 264 | 530 | 260 | 202 | 380 | 196 | M8 | <25 |
ZJR2-31320 | 132 | 264 | 530 | 260 | 202 | 380 | 196 | M8 | <25 |
ZJR2-31600 | 160 | 320 | 530 | 260 | 202 | 380 | 196 | M8 | <25 |
ZJR2-32500 | 200 | 400 | 530 | 260 | 202 | 380 | 196 | M8 | <25 |
ZJR1-32500 | 250 | 500 | 580 | 290 | 245 | 460 | 260 | M8 | <35 |
ZJR1-32800 | 280 | 560 | 580 | 290 | 245 | 460 | 260 | M8 | <35 |
ZJR1-33150 | 315 | 630 | 580 | 290 | 245 | 460 | 260 | M8 | <35 |
ZJR1-34000 | 400 | 800 | 630 | 330 | 245 | 500 | 265 | M8 | <40 |
ZJR1-34500 | 450 | 900 | 630 | 330 | 245 | 500 | 265 | M8 | <40 |
ZJR1-35000 | 500 | 1000 | 760 | 406 | 260 | 540 | 370 | M8 | <45 |
Item | Item Description | ||
Input Power Supply | Input Voltage | Three Phase 380V-15% ~ 415+10% | |
Frequency | 50/60Hz | ||
Adaptive Motor | Squirrel-cage three-phase asynchronous motor | ||
Starting Times | It is recommended not to exceed 20 times per hour. | ||
Control Mode | 1) Operation panel control; 2) Operation panel + external control; 3) External control; 4) External control + COM control; 5) Operation panel + external + COM control; 6) Operation panel + COM control; 7) COM control; 8) No start or stop operation. | ||
Start Mode | 1) Current-limiting start; 2) Voltage ramp start; 3) Kick start + current-limiting start; 4) Kick start + voltage ramp start; 5) Current ramp start; 6) Voltage current-limiting double closed-loop start. | ||
Stop Mode | 1) Soft stop; 2) Free stop. | ||
Protective Function | 1) Open loop protection for external instantaneous stop terminals; 2) Over-heat protection for soft starter; 3) Protection for too long starting time; 4) Input open phase protection; 5) Output open phase protection; 6) Unbalanced three-phase protection; 7) starting over current protection; 8) Running overload protection; 9) Under voltage protection for power voltage; 10) Over voltage protection for power voltage; 11) Protection for fault parameter setting; 12) Load short circuit protection; 13) Auto restart or incorrect wiring protection; 14) Incorrect wiring protection of external control stop terminals. | ||
Ambient | Place to be used | Indoor location with good ventilation free from corrosive gas and conductive dust. | |
Altitude | Below 3000M. It have to rise the rate power when the altitude is more than 3000M. | ||
Ambient Temperature |
-30~+55ºC |
||
Ambient Humidity | ≤90%RH without dew condensation. | ||
Vibration | <0.5G | ||
Structure | Protection Class | IP20 | |
Cooling Pattern | Natural wind cooling. | ||