Chziri Softstarter AC Soft Starter for Pump Sewage Treatment Plant

Task: Protection
Structure: Combination
Mathematical Model: Operation Panel Control
Signal: The Soft Starter Can Work When The Motor Starts
Function: Automatic Control, Protection
Certification: CCC, ISO: 9001, CE
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
ZJR2-3370/4370
Condition
New
Customized
Customized
Material
Iron Shell
Input Voltage
Three-Phase 380V-15% ~ 415+10%
Input Frequency
50/60Hz
Adaptive Motor
Squirrel-Cage Three-Phase Asynchronous Motor
Starting Times
It Is Recommended Not to Exceed 20 Times Per Hour
Stop Mode
1) Soft Stop; 2) Free Stop.
Control Mode 1
Operation Panel Control
Control Mode 2
Operation Panel + External Control
Control Mode 3
External Control
Control Mode 4
External Control + COM Control
Control Mode 5
Operation Panel + External + COM Control
Transport Package
Stardard Export Package
Specification
CE, ISO9001. CCC, SGS
Trademark
CHZIRI
Origin
Wenzhou, Zhejiang
HS Code
8537101990
Production Capacity
500000PCS/Year

Product Description

Main Features for  ZJR2 series soft starter

   ZJR2 series soft starter can work with three-phase,AC squirrel  cage induction asynchronous motor,The voltage is 320V~460V, 50HZ/60HZ and the current is 1200A and below.The soft starter is a device type.It's necessary to add breakers (short-circuit protection ) and AC contactor (Bypass) inside the cabinet.together with switches are made up of electric motor control circuit.
Chziri Softstarter AC Soft Starter for Pump Sewage Treatment Plant

  
ZJR2 device type can work without three-phase AC motor in the process of starting too big acceleration torque,and power supply system plays a protection from excessive current harvest dynamic impact role, has the following characteristics:

1.16 SCM control, intelligent all-digital display;

2.can be put into practice a soft starter control multiple motors;

3.Starting modes: Current limiting starter, Voltage ramp start , Kick start +current-limiting  start,kick start +voltage ramp start.Current ramp start.Voltage current-limiting double closed -loop start.

4.free stop  and soft stop,The stop time from 0 to 60 seconds can be arbitrary choosed

5.Over current,Overload,Open phase,instantaneous stop and other fault protection.
with the flow,over loading,lack phase,instantaneous stop,and other malfunction protection;

6.Easy installation,simple operation,strong function and reasonable prices;

Chziri Softstarter AC Soft Starter for Pump Sewage Treatment Plant

Technical Indications
Item Item Description
Input Power Supply Input Voltage Three Phase 380V-15% ~ 415+10%
Frequency 50/60Hz
Adaptive Motor Squirrel-cage three-phase asynchronous motor
Starting Times It is recommended not to exceed 20 times per hour.
Control Mode 1) Operation panel control; 2) Operation panel + external control; 3) External control; 4) External control + COM control; 5) Operation panel + external + COM control; 6) Operation panel + COM control; 7) COM control; 8) No start or stop operation.
Start Mode 1) Current-limiting start; 2) Voltage ramp start; 3) Kick start + current-limiting start; 4) Kick start + voltage ramp start; 5) Current ramp start; 6) Voltage current-limiting double closed-loop start.
Stop Mode 1) Soft stop; 2) Free stop.
Protective Function
Open loop protection for external instantaneous stop terminals; 2) Over-heat protection for soft starter; 3) Protection for too long starting time; 4) Input open phase protection; 5) Output open phase protection; 6) Unbalanced three-phase protection; 7) starting over current protection; 8) Running overload protection; 9) Under voltage protection for power voltage; 10) Over voltage protection for power voltage; 11) Protection for fault parameter setting; 12) Load short circuit protection; 13) Auto restart or incorrect wiring protection; 14) Incorrect wiring protection of external control stop terminals.

Ambient
Place to be used Indoor location with good ventilation free from corrosive gas and conductive dust.
Altitude Below 3000M. It have to rise the rate power when the altitude is more than 3000M.
Ambient
Temperature

-30~+55ºC
Ambient Humidity ≤90%RH without dew condensation.
Vibration <0.5G
Structure Protection Class IP20
Cooling Pattern Natural wind cooling.


Scope of application for ZJR2 Soft Starter :

  ZJR2 series soft starter motor applies to centrifuges,blower,compressor,transport planes,mixer,rolling ball mill broken machines and mechanical equipment motor starter.
Chziri Softstarter AC Soft Starter for Pump Sewage Treatment Plant

DIMENSION:(UNIT:MM)
Soft starter Model Rated Power(KW) Rated Current (A) Outline Size Install Size Net Weight
H1 W1 D H2 W2 d
ZJR2-3345 45kw 90A 270 145 159 245 130 M6 <25


CHZIRI Soft Starter Package

Chziri Softstarter AC Soft Starter for Pump Sewage Treatment PlantChziri Softstarter AC Soft Starter for Pump Sewage Treatment Plant

FAQ                       
1.Can I get some samples?
Yes,Sample order is available for quality check and market test .But you have to pay for it.

2.What's delivery time?
It usually takes about 3-5 working days for small order and 10-15 days for big order.

3.What's your payment terms?
We usually accept all kinds of payment terms.Such as T/T,L/C,Western Union.Cash.

4.What's your warranty terms?
We offer 12 months warranty time .

5.Do you have the products in stock?
Depends on your request,We have standard models in stock.Some special products and big order will be newly produced according to your order.

6.Can I mix different power in one container.
Yes,Different models can be mixed up in one container,even one order.

7.How does your factory do the quality control?
Quality is priority,we always attach the importance to quality control from the beginning to the end of the production.every product will be fully assembled and carefully tested before packing and shipping.

8.Can you sell spare parts ?
If you are using CHZIRI products .we can sell spare parts to you.But we couldn't sell the half-finished products.

9.I would like to know if you have a partner for export?
Yes.CHZIRI Electrical have the right to export and can sell electrical product all over the world.

10.Can you make the inverter and soft starter control boards (switchgear)?
Yes.We have a lot of experience to design frequency inverter and soft starter cabinet according to your request.But you can send us the wiring diagram .

11.Can the inverter connect with computer?
Yes.All inverters have built-in RS485 port .and support Modbus communication protocol.

12.How can I trust you ?
The core of CHZIRI electrical culture is honesty and loyalty .our company has been audited and approved ISO9001,CE.CCC. Assessment report will could be sent to you by e-mail.also.we are the made-in-china's gold supplier since 2008.Now we have clients all around the world .

CHZIRI PACKAGE
Chziri Softstarter AC Soft Starter for Pump Sewage Treatment Plant



CHZIRI CLIENTS
Chziri Softstarter AC Soft Starter for Pump Sewage Treatment Plant



CHZIRI CERTIFICATE
Chziri Softstarter AC Soft Starter for Pump Sewage Treatment Plant



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now