Customization: | Available |
---|---|
Application: | General Transducer, Can Control and Drive The Speed of Motor |
Output Type: | Triple |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | Power(kW) | H | H1 | W | W1 | D | d | Packing Size(mm) | G.W.(kg) |
ZVF300-G015/P018T4MD | 15kW/18.5kW | 380 | 360 | 220 | 140 | 230 | 6 | 610*435*300mm/2PCS | 25 |
ZVF300-G018/P022T4MD | 18.5kW/22kW | 380 | 360 | 220 | 140 | 230 | 6 | ||
ZVF300-G022/P030T4M | 22kW/30kW | 460 | 443 | 260 | 177 | 268 | 6 | 555X375X360mm/1PCS | 25 |
ZVF300-G030/P037T4M | 30kW/37kW | 460 | 443 | 260 | 177 | 268 | 6 | ||
ZVF300-G037/P045T4M | 37kW/45kW | 620 | 603 | 265 | 182 | 300 | 8 | 700X375X400mm/PCS | 36 |
ZVF300-G045/P055T4M | 45kW/55kW | 620 | 603 | 265 | 182 | 300 | 8 | ||
ZVF300-G055/P075T4M | 55kW/75kW | 620 | 603 | 265 | 182 | 300 | 8 | ||
ZVF300-G075/P090T4M | 75kW/90kW | 720 | 702 | 365 | 240 | 360 | 9 | 800X495X485mm/1PCS | 64 |
ZVF300-G090/P110T4M | 90kW/110kW | 720 | 702 | 365 | 240 | 360 | 9 | ||
ZVF300-G110/P132T4M | 110kW/132kW | 720 | 702 | 365 | 240 | 360 | 9 |
Item | Item Description | |
Control Function | Automatic energy-saving operation | Auto optimize V/F curve according to the load changes to realize the energy saving operation. |
Auto voltage regulation(AVR) | When the network voltage changes, it can regulate PWM output automatically to maintain constant voltage. | |
Built-in PID | This can form a convenient closed-loop control system (CLCS)and is applicable to pressure control, flow control and other process control . | |
Operation Function | Operating command | Operation panel control ,external terminal control and COM control |
Frequency setting | Keypad potentiometer setting , operation panel setting,. external terminal UP/DOWN setting, analog voltage signal or external potentiometer setting , analog current signal setting .terminal combination setting ,485 COM setting and so on. | |
Input Signal | Forward/Reverse signal\multi-speed signal \fault signal \ reset signal etc. |
|
Output signal | Programmable relay\open collector output \Fault signal output. | |
Multi-function analog and digital output terminal | This can realize the output of frequency current and other physical quantity by output 0-10V or 0-20mA DC signal and 0-10KHz digital signal output. | |
Braking function | Dynamic braking | With an external braking resistor, the maximum braking torque may reach 100%. |
DC Braking | This can be selected when the motor starts or stops with the action frequency of 0-20Hz,action current level of 0-100% and actuation time of 0-30sec., which can be set in sequence. | |
Other Function | Skip frequency\Jog function\Counter \Rotation speed tracking\Momentary power loss restart \Frequency upper/lower limiting\Acceleration/ Deceleration mode can be adjusted \Frequency meter and Voltmeter output \Multi-speed/ program running \Two wire mode/ three wire mode control \Wobble frequency control\Multi-function input terminal selection \Fault auto reset\RS485 serial communication . | |
Protection Function | Input phase loss protection\Over current protection \Overload protection\Over voltage protection \Under voltage protection\Over heat protection ect. |